About 54 results
Open links in new tab
  1. Egress Capacity Calculator - 2024 IBC

    Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020.3, and Section 1010.1.1 for doors.

  2. Occupancy Classification for Townhouse: R-2 or R-3?

    Oct 17, 2009 · R-2: "Residential occupancies containing more than two dwelling units" If each townhouse is a seperate structure, than it only contains one dwelling unit. That makes it R-3, yes?

  3. S-1 occupancy, occupant load | The Building Code Forum

    Mar 15, 2022 · 2015 IBC, table 1004.1.2, what does a s-1 storage occupancy (repair garage with ordinary hazard) fall under for the occupant load factor? im thinking industrial at 200 sf per person

  4. 1, single user, unisex toilet room in coffee shop, per 2021 IBC

    Feb 24, 2025 · The IBC Commentary language for exception #5 confirms this. There is also the exception under the calculations portion , 2902.1.1, reading "Distribution of the sexes is not required …

  5. Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and ...

    Oct 16, 2009 · Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted. It outlines the scope, purpose, and administrative …

  6. Fire Separation Distance Between New and Existing Building with …

    Feb 7, 2024 · From the 2021 IBC Commentary: The Commentary says: Fire separation distance is the distance from the exterior wall of the building to one of the three following locations, measured …

  7. IBC 1013.8 window sill height and 4" opening limitation

    2012 IBC 1013.8 states: Operable sections of windows shall not permit openings that allow passage of a 4-inch diameter sphere where such openings are located within 36 inches of the finished floor [and …

  8. Handrail clearances IBC vs NFPA - The Building Code Forum

    Oct 22, 2009 · Around here we never use NFPA 101 but it has come to my attention that NFPA 101 requires a 2 1/4" min clearance from the wall to the handrail. Is this a type-o with NFPA? We have …

  9. Egress through Intervening Spaces - The Building Code Forum

    Feb 17, 2022 · It was mentioned that the path cannot cross through intervening spaces. The large room is the Multipurpose/Gym. I've been making evac signs as such for a while and this is the first I've …

  10. Equipment Platforms: IBC or OSHA - The Building Code Forum

    Mar 29, 2022 · I'm trying to locate any specific language in the 2015 IBC ("code") regarding when to use OSHA for the means of egress and design of walkway/stairs that serve equipment platforms. I find it …